1.1007.54.xxx Particulate-hygro-thermo-baro sensor compact

The particulate-hygro-thermo-baro sensors from our COMPACT series are designed to meas-ure relative humidity, air temperature and barometric air pressure, and fine dust values PM10 and PM 2.5.The use

  • Product Name:Particulate-hygro-thermo-baro sensor compact
  • Model:1.1007.54.xxx
  • Maunufactor:Thies Clima
  • Country:DE

The particulate-hygro-thermo-baro sensors from our COMPACT series are designed to meas-ure relative humidity, air temperature and barometric air pressure, and fine dust values PM10 and PM 2.5.
The use of high-quality sensors for the parameters to be measured allows the sensor to achieve the following:
• High long-term stability
• Virtually linear characteristic
• Good dynamic behaviour
• Dewing resistance
• Low temperature coefficients
• Small hysteresis

Interfaces:
• digital outputs MODBUS RTU /­ THIES
• plug connection
• calble connection
 
The sensors are primarily intended for use in distributed fine dust measurement outdoors. For example, the fine dust distribution in a district can be recorded using several hygro-thermo-baro sensors. Thanks to its universal interface, the sensor can also be used as an individual solution in any suitable application.
The interface to the device is digital and consists of an RS485 interface in half duplex mode. In conjunction with ID-based communication the interface enables operation of the sensors in a bus system.

Two data protocols are available:
• ASCII (THIES format)
• Binary (MODBUS-RTU)

The sensor is equipped with a built-in pressure sensor, as well as a replaceable hygro-thermo module for recording the air temperature and relative humidity, as well as a replaceable fine dust sensor. The durable sensors are adjusted and calibrated at the factory.

Particulate
Measuring range0 … 1000 µg/­m³
AccuracyPM2.5 @ -10…+60 °C
± 10 µg/­m³ @ 0 … 100 µg/­m³
± 10 % of measuring @ 100 … 1000 µg/­m³
PM10 @ -10…+60 °C
± 25 µg/­m³ @ 0 … 100 µg/­m³
± 25 % of measuring @ 100 … 1000 µg/­m³
(with no fog)
Temperature
Measuring range-40 … +60 °C
Accuracy± 0.1 °C @ -40 ... +60 °C @ moved air > 2 m/­s
Rel. Humidity
Measuring range0 … 100 % rel. Humidity
AccuracyTyp. ± 1,5 % r. H. @ 25 °C and < 80 % r. H.
2 % r. H. over the complete measuring range
Air pressure
Measuring range300 … 1200 hPa
Accuracy± 0.25 hPa @ -20 … +60°C @ 800 … 1100 hPa
± 0.50 hPa @ -20 … +60°C @ 600 … 800 hPa
Interface
TypeRS 485 HD
Data format8N1, 8N2, 8E1, 8E2, 8O1, 8O2, 7E1, 7N1
Baud rate2400 ... 57600 Baud
Operating voltage
Battery connection2x 12 ... 30 V DC
General
Ambient conditions-20 ... +70 °C
0 ... 100 rel. humidity, including condensation
Current loadMeasurement electronics:
typ. 360 mW
max. 500 mW
Ventilation:
2 W
HousingStainless steel, polycarbonate
ProtectionIP53
DimensionØ 120 x 317
Weightaprox. 1.25 kg