ECOPROBE 5

These products combine the advantages of advanced excellent PID and IR technology. The ECOPROBE 5 replaces a number of separate analysing devices with one small, compact instrument. It provides the us

  • Product Name:ECOPROBE 5
  • Maunufactor:RS DYNAMICS
  • Country:Switzerland

These products combine the advantages of advanced excellent PID and IR technology. The ECOPROBE 5 replaces a number of separate analysing devices with one small, compact instrument. It provides the user with the in-situ measurement of organic contaminants with selective analyses of methane, group of common petroleum hydrocarbons, CO2, O2, atmospheric pressure, sampling vacuum and soil temperature. A fully integrated automatic GPS data-logger, independent automatic monitoring station operation as well as powerful computer come with the ECOPROBE 5 as optional accessories.


The main advantages of the ECOPROBE 5 range are:


  • Simultaneous in-situ measurement using the time-integrated photo-ionization analyzer (PID) and 3-channel selective infra-red analyzer (Selective methane, CO2, Group of petroleum hydrocarbons, with reference channel).

  • Additional measurement of N2O, H2S (optional HW configuration)

  • Reliable Oxygen reading.

  • Automatic re-zeroing before each measurement ensures perfect baseline stability and high accuracy of the resulting values.

  • Real-time correction of measured values for soil porosity, atmospheric/pumping pressure and temperature.

  • Ruggedized, light-weight and compact strong construction make it ideal for use in the field.

  • Easy-to-read graphic display, user-friendly special operating system and data acquisition software.

  • Automatic Monitoring Station Mode with no additional hardware/software.

  • Automatic logging of all measured data.

  • A powerful surface data-logging system for transparent, fast 3-D graphic visualization.

  • Fully integrated automatic GPS position logger (up to centimeter accuracy on request)

  • An integral user-calibration facility provides on-site fast calibration and advanced whole dynamic range calibration.

  • IrDA/RS232 interface with Win XP/w2k/Vista/7/8/10/11 compatible ECOPROBE_VIEW software, providing data transfer, graphic data acquisition and data spreadsheet for 3-D graphic outputs.

  • Automatic date/time record for all stored data, built in adjustable acoustic alarm for all measured values.

  • Possible integration to the monitoring stations network

Dimensions: 105 x 260 x 170 mm (including handle)

Weight: 3 kg

Shipping Weight: 13 kg (incl. probes, calibration kit, accessories)

Power Supply: internal rechargeable battery

Memory Capacity: about 100 000 measurements

Output: RS 232 cable or infra-red interface

Data Format: ASCII, EXCEL, GRAPHER, SURFER or user programmable format

Display: full graphic back-lite LCD

Keyboard Input: multi-function sealed keys

Operating System: Win 9x/NT4.0 /2000/7/8/10/11 compatible

Internal Air Pump: membrane vacuum pump with programmable speed 0.25 – 4 liters/minute

Calibration: Automatic calibration of all measuring channels

ECOPROBE 5 is the highly sensitive, portable multi-function analytical system which provides optimum power & flexibility for efficient, low-cost Soil Contamination Surveys / Toxic Gas Monitoring with the following features:

  • Simultaneous in-situ measurement of using the time integrated photo-ionization analyzer (PID) and 3-channel selective infra-red analyzer (IR).

  • Additional measurement of N2O, H2S (optional HW configuration)

  • Reliable Oxygen reading.

  • Automatic re-zeroing before each measurement ensures perfect baseline stability and high accuracy of the resulting values. Ruggedized, light-weight and compact of strong construction making it entirely suitable for the field environment. Easy to read graphic display, user-friendly operating system & data acquisition software.

  • Real time correction of measured values for soil porosity, atmospheric / pumping pressure and temperature.

  • Automatic Monitoring Station Mode without any additional hardware/software.

  • Automatic logging of all measured data. A powerful surface data logging system for transparent and fast 3-D graphic visualization.

  • Fully integrated automatic GPS Position Logger (up to centimeter accuracy) is referenced to the WDS 84 coordinate system and also supports surface format “in meters” for un-demanding operator navigation.

  • An integral user calibration facility provides on-site fast calibration and advanced whole dynamic range calibration.

  • IrDA/RS232 interface with Win9x/NT4.0 /2000/7/8/10/11 compatible ECOPROBE_VIEW software, providing data transfer, graphic data acquisition and data spreadsheet for 3-D graphic outputs.

  • Automatic date/time record for all stored data, built in adjustable acoustic alarm for all measured values.

PID

(Photo-ionization analyzer) measures total level of volatile organic compounds (VOCs) and other toxic gases including chlorinated hydrocarbons to sub-ppb levels with the following characteristics:

  • Detection limit: 2 ranges 0.1 ppm / 0.1 ppb 0.1 ppb zero stability

  • Response time: 0.1 sec;

  • Sampling rate: 10 samples/sec.

  • ppb resolution, choice of peak or integrated values

  • Indication of soil porosity/permeability

  • Internal automatic calibration for quantitative vapor phase determination for about 200 compounds

  • Zero response for Methane (Methane measured separately by IR unit)

  • Large dynamic range (0.1 ppb to 4000 ppm), fast response

  • Ion lamp 10.6/10.2 eV (other energy levels are optional)

  • ppm or mg/m3 (ppb or µg/m3) output

IR

(Infra-red analyzer) comprises 3 independent channels for selective analyses of Methane, Petroleum Hydrocarbons and CO2 (plus internal reference channel) with ppm resolution and the following characteristics:

  • Methane: 0-500 000 ppm, detection limit 200ppm (in the field) / 100 ppm (in the laboratory condition)

  • Petroleum Hydrocarbons: 0-500 000 ppm, detection limit 30 ppm (for THC)

  • Carbon Dioxide: 0-500 000 ppm, detection limit 20ppm

  • Reference Channel (internal)

  • Ranges of other possible channels optional / selectable

  • Response time: 0.8 sec

  • Sampling rate: 10 samples/sec

  • ppm or mg/m3 output

Other readings

Oxygen: 0-100 %

N2O: 0-10000 ppm (optional)

H2S: 0-50 ppm or 0-2000 ppm (optional according HW configuration)

Soil temperature: oF, oC; (+/- 0.1oC, resolution 0.01oC)

Sampled gas temperature: oF, oC

Ambient pressure / sampling vacuum (mbar, Torr, psi, kPa), accuracy 0.1%, resolution 0.01%