The TR75A2 is a temperature logger with two thermocouple (K, J, T, E, S, R) sensor connections. It is capable of measuring temperatures ranging from -199 to 1760°C, and can be used in very high temperatures such as in a plant furnace or in deep freezers where temperatures reach very low levels.
Functional buttons on the device allow you to make settings and start/stop recording. Use the wireless LAN feature (compatible with the enterprise communication) to auto-upload data to the cloud for anytime anywhere access and receive warning notifications. By using Bluetooth or USB, you can configure device settings, generate reports, download data, and view the uploaded data. You can download the recorded data and change the device settings on a PC via USB Connection. A USB cable (option US-15C) is required to connect the device to a PC.
The software application used with the TR75A2 has a "Vaccine Mode", which meets or exceeds CDC requirements for VFC, and is suitable for monitoring and recording vaccine temperatures. TR75A2 is useful not only in pharmaceutical and medical reseach labs, hospitals, but also in factories and other facilities.
Note: We do not handle the sale of Thermocouple sensors.
The TR75A2 uses a wireless LAN access point to auto-upload recorded data and warning notifications to our free-of-charge cloud-based “T&D WebStorage Service”. You can download data and configure device settings using our dedicated app "TR7 for Windows (for Windows)" or "T&D Thermo (for smartphone / tablet)". By using our Windows software “T&D Graph”, you can easily view and analyze data from a PC.
Channels: Temperature 2ch, Thermocouple: Type K, J, T, E, S, R (sensor not provided)
Range: -199~1760°C
Comm Interfaces : Wireless LAN, USB, Bluetooth 4.2 (Bluetooth Low Energy)
Waterproof Capacity: None
TR75A2 Operational Differences by Measurement Mode
Max/Min temperature reading since the start of recording or reset (via buttons or software/app) | Max/Min recorded value since the start of recording or reset (via buttons or software/app) |
30 sec to 60 min (9 selections) | 0 sec. |
Warning alarms for exceeding a set upper and lower limit and for sensor errors will both disappear when the warning condition is resolved. | Warning alarms for exceeding a set upper and lower limit will not disappear even after a value returns to within the threshold range. Warning alarms for sensor errors will disappear upon return to normal. |
Note: The TR7A2 series is the successor model of our TR7A series.
Comparison of TR7A2 / TR7A Features